Minimizing exposure to allergens and remediating the environment play a critical role in the treatment of asthma and allergies. The most effective environmental
control measures are tailored multifaceted interventions which include education, thorough cleaning, using high efficiency particulate Fer-1 air ( HEPA) filters, integrated pest management, and maintenance of these practices.”
“Background: Palutop+4 (All. Diag, Strasbourg, France), a four-band malaria rapid diagnostic test (malaria RDT) targeting the histidine-rich protein 2 (HRP-2), Plasmodium vivax-specific parasite lactate dehydrogenase (Pv-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH) was evaluated in a non-endemic setting on stored whole blood 123 samples from international travellers suspected of malaria.\n\nMethods: Microscopy corrected by PCR was the reference method. Samples include those infected by Plasmodium falciparum (n
= 323), Plasmodium vivax (n = 97), Plasmodium Selleckchem Alvespimycin ovale (n = 73) and Plasmodium malariae (n = 25) and 95 malaria negative samples.\n\nResults: The sensitivities for the diagnosis of P. falciparum, P. vivax, P. malariae and P. ovale were 85.1%, 66.0%, 32.0% and 5.5%. Sensitivities increased at higher parasite densities and reached 90.0% for P. falciparum >100/mu l and 83.8% for P. vivax >500/mu l. Fourteen P. falciparum samples reacted with the Pv-pLDH line, one P. vivax sample with the HRP-2 line, and respectively two and four P. ovale and P. malariae samples reacted with the HRP-2 line. Two negative samples gave a signal with the HRP-2 line. Faint and weak line intensities were observed for 129/289 (44.6%) HRP-2 lines in P. falciparum samples, for 50/64 (78.1%) Pv-pLDH STI571 lines in P. vivax samples and for 9/13 (69.2%) pan-pLDH lines in P. ovale and P. malariae samples combined. Inter-observer reliabilities for positive and negative readings were excellent for the HRP-2 and Pv-pLDH lines (overall agreement >92.0% and kappa-values for each pair of readers >= 0.88), and good for the pan-pLDH line (85.5% overall agreement and kappa-values
>= 0.74).\n\nConclusions: Palutop+4 performed moderately for the detection of P. falciparum and P. vivax, but sensitivities were lower than those of three-band malaria RDTs.”
“PurposeMyocardial T-1 mapping is an emerging technique that could improve cardiovascular magnetic resonance diagnostic accuracy. In this study, a variable flip angle approach with B-1 correction is proposed at 3T on the myocardium, employing standard 3D spoiled fast gradient echo and echo planar imaging sequences.\n\nMethodsThe method was tested on phantoms to determine the set of standard 3D spoiled fast gradient echo angles adapted to myocardial T-1 measurements and was compared to the inversion-recovery spin-echo reference T-1 method. Seven volunteers underwent magnetic imaging resonance to acquire myocardial T-1 maps and T-1 values of the human heart.